The assessment of water supply system efficiency and water quality in Standerton, Lekwa Municipality, Mpumalanga, South Africa

dc.contributor.advisorMakungo, Rachel
dc.contributor.advisorSengani, Ben
dc.contributor.authorShikwambana, Pamlah Patience
dc.date2025
dc.date.accessioned2025-09-16T00:10:56Z
dc.date.available2025-09-16T00:10:56Z
dc.date.issued2025-09-05
dc.descriptionMENVSCI in Hydrology and Water Resources
dc.descriptionDepartment of Earth Sciences
dc.description.abstractMost municipalities in South Africa face significant challenges in managing their water treatment plants effectively, often due to a lack of technical expertise, insufficient staffing and poor maintenance planning. These result in poor water quality, frequent supply interruptions and failure to comply with regulatory standards. Furthermore, difficulties in retaining skilled personnel and misallocation of resources exacerbate the problem, exposing communities to health risks and unreliable water services that undermine sustainable water supply efforts. This study evaluated the efficiency of the water supply system and assessed water quality at the Standerton Water Treatment Plant (SWTP) in Lekwa Local Municipality, Mpumalanga, South Africa. The assessment focused on operational performance, distribution effectiveness and compliance with national and international water quality standards. Data were collected through field observations, water meter readings and five years of water quality data obtained from the Department of Water and Sanitation (DWS) Mpumalanga from 2016 to 2020. Efficiency analysis involved comparing water quantity against demand, quantifying water losses and assessing distribution reliability. Water quality was evaluated by comparing measured parameters to guidelines set by the World Health Organization (WHO), South African National Standard (SANS-241), and Department of Water Affairs (DWA). Parameters analyzed included microbiological indicators such as Escherichia coli and total coliforms, as well as physicochemical variables like pH, turbidity, free chlorine, electrical conductivity (EC), total dissolved solids (TDS), manganese (Mn), and iron (Fe). The results showed that pH, EC, and TDS consistently met the acceptable limits throughout the five-year period, indicating stable performance in these aspects. However, free chlorine, turbidity, manganese and iron persistently exceeded regulatory limits, signaling systemic issues within the treatment process. These ongoing exceedances point to challenges such as inadequate chemical dosing, poor filtration, ineffective disinfection and possible contamination within the distribution network. Of particular concern was the detection of E. coli, suggesting faecal contamination and increased risk of waterborne diseases. The elevated turbidity, Mn and Fe levels also affected water aesthetics, leading to consumer complaints and diminished trust in the municipal water supply. Operational challenges identified include aging infrastructure, poor maintenance practices, inaccuracies in chemical dosing and delayed responses to equipment failures such as malfunctioning pumps and burst pipelines. The plant operates beyond its designed capacity; although licensed for 27 ML/day with a design capacity of 37 ML/day, SWTP treated 43 ML/day while the estimated demand was approximately 45 ML/day. This overcapacity strains the plant, contributing to the suboptimal treatment performance. Additionally, the plant did not comply with regulatory requirements mandating the measurement of critical parameters pH, turbidity and EC at two-hour intervals, due to a lack of necessary analytical equipment. Staffing issues were prevalent, with many process controllers lacking formal training and qualifications necessary for effective plant management. The study also highlighted real-world impacts on local businesses, such as Goldie Chicken, which experiences water outages lasting up to two days per week. These interruptions have resulted in reduced production, workforce retrenchment and the inability to meet market demand. To improve water service delivery, it is imperative for the municipality to invest in upgrading water treatment infrastructure, ensure that plant personnel meet minimum qualification standards and implement continuous training programs to build technical capacity. Strengthening operational management and maintenance practices is essential to achieving regulatory compliance, safeguarding public health and securing a sustainable water supply for the Standerton community.
dc.description.sponsorshipDepartment of Water and Sanitation
dc.format.extent1 online resource (xiii, 100 leaves): color illustrations, color maps
dc.identifier.apacitationShikwambana, P. P. (2025). <i>The assessment of water supply system efficiency and water quality in Standerton, Lekwa Municipality, Mpumalanga, South Africa</i>. (). . Retrieved from en_ZA
dc.identifier.chicagocitationShikwambana, Pamlah Patience. <i>"The assessment of water supply system efficiency and water quality in Standerton, Lekwa Municipality, Mpumalanga, South Africa."</i> ., , 2025. en_ZA
dc.identifier.citationShikwambana, P.P. 2025. The assessment of water supply system efficiency and water quality in Standerton, Lekwa Municipality, Mpumalanga, South Africa. . . en_ZA
dc.identifier.ris TY - Dissertation AU - Shikwambana, Pamlah Patience AB - Most municipalities in South Africa face significant challenges in managing their water treatment plants effectively, often due to a lack of technical expertise, insufficient staffing and poor maintenance planning. These result in poor water quality, frequent supply interruptions and failure to comply with regulatory standards. Furthermore, difficulties in retaining skilled personnel and misallocation of resources exacerbate the problem, exposing communities to health risks and unreliable water services that undermine sustainable water supply efforts. This study evaluated the efficiency of the water supply system and assessed water quality at the Standerton Water Treatment Plant (SWTP) in Lekwa Local Municipality, Mpumalanga, South Africa. The assessment focused on operational performance, distribution effectiveness and compliance with national and international water quality standards. Data were collected through field observations, water meter readings and five years of water quality data obtained from the Department of Water and Sanitation (DWS) Mpumalanga from 2016 to 2020. Efficiency analysis involved comparing water quantity against demand, quantifying water losses and assessing distribution reliability. Water quality was evaluated by comparing measured parameters to guidelines set by the World Health Organization (WHO), South African National Standard (SANS-241), and Department of Water Affairs (DWA). Parameters analyzed included microbiological indicators such as Escherichia coli and total coliforms, as well as physicochemical variables like pH, turbidity, free chlorine, electrical conductivity (EC), total dissolved solids (TDS), manganese (Mn), and iron (Fe). The results showed that pH, EC, and TDS consistently met the acceptable limits throughout the five-year period, indicating stable performance in these aspects. However, free chlorine, turbidity, manganese and iron persistently exceeded regulatory limits, signaling systemic issues within the treatment process. These ongoing exceedances point to challenges such as inadequate chemical dosing, poor filtration, ineffective disinfection and possible contamination within the distribution network. Of particular concern was the detection of E. coli, suggesting faecal contamination and increased risk of waterborne diseases. The elevated turbidity, Mn and Fe levels also affected water aesthetics, leading to consumer complaints and diminished trust in the municipal water supply. Operational challenges identified include aging infrastructure, poor maintenance practices, inaccuracies in chemical dosing and delayed responses to equipment failures such as malfunctioning pumps and burst pipelines. The plant operates beyond its designed capacity; although licensed for 27 ML/day with a design capacity of 37 ML/day, SWTP treated 43 ML/day while the estimated demand was approximately 45 ML/day. This overcapacity strains the plant, contributing to the suboptimal treatment performance. Additionally, the plant did not comply with regulatory requirements mandating the measurement of critical parameters pH, turbidity and EC at two-hour intervals, due to a lack of necessary analytical equipment. Staffing issues were prevalent, with many process controllers lacking formal training and qualifications necessary for effective plant management. The study also highlighted real-world impacts on local businesses, such as Goldie Chicken, which experiences water outages lasting up to two days per week. These interruptions have resulted in reduced production, workforce retrenchment and the inability to meet market demand. To improve water service delivery, it is imperative for the municipality to invest in upgrading water treatment infrastructure, ensure that plant personnel meet minimum qualification standards and implement continuous training programs to build technical capacity. Strengthening operational management and maintenance practices is essential to achieving regulatory compliance, safeguarding public health and securing a sustainable water supply for the Standerton community. DA - 2025-09-05 DB - ResearchSpace DP - Univen KW - Surface Water KW - Water Quality KW - Efficiency KW - Sustainability KW - Water Balance KW - Water Loss LK - https://univendspace.univen.ac.za PY - 2025 T1 - The assessment of water supply system efficiency and water quality in Standerton, Lekwa Municipality, Mpumalanga, South Africa TI - The assessment of water supply system efficiency and water quality in Standerton, Lekwa Municipality, Mpumalanga, South Africa UR - ER - en_ZA
dc.identifier.urihttps://univendspace.univen.ac.za/handle/11602/2943
dc.identifier.vancouvercitationShikwambana PP. The assessment of water supply system efficiency and water quality in Standerton, Lekwa Municipality, Mpumalanga, South Africa. []. , 2025 [cited yyyy month dd]. Available from: en_ZA
dc.language.isoen
dc.relation.requiresPDF
dc.rightsUniversity of Venda
dc.subjectSurface Water
dc.subjectUCTDen_ZA
dc.subjectWater Quality
dc.subjectEfficiency
dc.subjectSustainability
dc.subjectWater Balance
dc.subjectWater Loss
dc.subject.ddc363.61096827
dc.subject.lcshWater-supply -- South Africa -- Mpumalanga
dc.subject.lcshWater quality -- South Africa -- Mpumalanga
dc.subject.lcshMunicipal water supply -- South Africa -- Mpumalanga
dc.subject.lcshWater resources development -- South Africa -- Mpumalanga
dc.titleThe assessment of water supply system efficiency and water quality in Standerton, Lekwa Municipality, Mpumalanga, South Africa
dc.typeDissertation

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Dissertation - Shikwambana, p. p.-.pdf
Size:
3.04 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: